DPM Gen2 Series 250-1750 kVA

Uplevel Performance, Ensure Protection

Features and Benefits

  • OPEX Savings
    • AC-AC efficiency up to 97.3%, efficiency optimization at light loads saves energy costs
    • Clean mode (voltage independent mode) up to 99% efficient guarantees the optimum power condition while maintaining the highest level of efficiency
    • Optimizes energy cost with off-peak charging, avoiding peak-time expense
    • Elevates grid stability through responsive demand reduction and fast frequency regulation, triggers upon utility requests for eligible bill subsidies
  • Impeccable Reliability
    • Assures smooth power transitions with integrated Synchronized Multiple Bus (SMB), minimizing transformer inrush currents and maintaining balanced power from dual sources
    • Parallels up to 8 units for redundancy or expansion, supported by N+1 internal redundancy in power modular configuration
    • Maximizes UPS performance and lifespan with self-diagnosis and key component analysis
  • Ultimate Availability
    • Lithium-ion battery ready. Adjustable battery charging voltage adapts to multiple types of batteries
    • Seamless power shifts to generator with an advance power walk-in function, pausing during frequency issues for smooth transitions without unnecessary generator sizing expansion
    • Grid interactive application. Provides corrective operation for unstable renewal energy sources with an innovative topology design that handles grid and battery power at the same time
    • Easy mounting/cabling that supports both top and bottom cable entry and full front access

Available to Order

Models

Overview

How to Buy

Click “WhatsApp Us” or “Get a Quote” above to buy Nuvo-8111 from APulsar Technologies, NEOUSYS official distributor.

Purchase walk-in from our office in Petaling Jaya, or order online and enjoy fast delivery across Kuala Lumpur and the entire Malaysia.

Introduction

Selected by leading global cloud providers, Delta’s DPM Gen2 introduces advanced features for enhanced efficiency and reliability. This includes OPEX savings with up to 97.3% AC-AC efficiency and improved grid stability. Synchronized Multiple Bus (SMB) and parallel scalability ensures flawless reliability, making it the ideal solution for fortified hyperscale data centers.

Specifications

Power Rating

⦁ DPM G2-250K: 250 kVA / 250 kW
⦁ DPM G2-500K: 500 kVA / 500 kW
⦁ DPM G2-750K: 750 kVA / 750 kW
⦁ DPM G2-1000K: 1000 kVA / 1000 kW
⦁ DPM G2-1250K: 1250 kVA / 1250 kW
⦁ DPM G2-1500K: 1500 kVA / 1500 kW
⦁ DPM G2-1750K: 1750 kVA / 1750 kW

Parallel Configuration: Up to 8 units

  • Nominal Voltage: 380/400/415 Vac, 3P3W+PE or 3P4W+PE
  • Voltage Range: 323-477 Vac (100% load)
  • Frequency Range: 40-70 Hz
  • Total Harmonic Distortion (THDi): < 3% (100% resistive load)
  • Power Factor: > 0.99 (100% load)
  • Short Circuit Withstand Rating
    ⦁ DPM G2-250~750K: 65 kA
    ⦁ DPM G2-1000~1750K: 100 kA
  • Connection: Single or dual feed

  • Nominal Voltage: 380/400/415 Vac, 3P3W+PE or 3P4W+PE
  • Voltage Regulation: ±1% (static)
  • Frequency: 50/60 ± 0.05 Hz
  • Total Harmonic Distortion (THDv): < 1% (linear load)
  • Power Factor: 1
  • Overload Capability: < 110%: continues, 110-125%: 10 mins, 126-150%: 1 min, > 150%: 1 sec
  • Current Crest Ratio: 3:1
  • Online Mode: Up to 97.3%
  • Clean Mode (VI): Up to 99%
  • Battery Type: VRLA, Vented lead-acid, Lithium-ion, Ni-Zinc
  • Nominal Voltage: 480 Vdc
  • Quantity: 34-35(2), 36-46 pcs (VRLA 12 V)
  • Charge Current
    ⦁ DPM G2-250K: 125 A
    ⦁ DPM G2-1000K: 500 A
    ⦁ DPM G2-1250K: 625 A
  • Protection Design: Battery shunt trip x1, Battery temperature detection x4, Battery breaker status dry contact x1
  • Display: 10-inch color touchscreen
  • Port:
    Smart slot x2, Modbus (RS-485) port x1, REPO port x1, Input dry contact x6, Output dry contact x6, Synchronized Multiple Bus (SMB) x2, Breaker status detection x4, EMS/Console port x1, Ethernet x1
  • Protocols: SNMP, Modbus RTU, Modbus TCP/IP, HTTP(S), SNTP, SMTP, BOOTP, DHCP
  • Dimensions (W x D x H)
    ⦁ DPM G2-250K: 1030 x 990 x 2000 mm
    ⦁ DPM G2-1000K: 3070 x 990 x 2000 mm
    ⦁ DPM G2-1250K: 3400 x 990 x 2000 mm
  • Net Weight
    ⦁ DPM G2-250K: 676 kg
    ⦁ DPM G2-1000K: 2450 kg
    ⦁ DPM G2-1250K: 2836.3 kg
  • Operating Temperature: 0 to 40°C
  • Humidity: 0-95% (non-condensing)
  • Altitude: 0-2,000 m (derating 1%/100m from 1,001-2,000 m)
  • Safety: CE, UL
  • EMC: IEC 62040-2, FCC Class A
  • Performance: IEC 62040-3
  • Sustainability: RoHS, REACH, Energy Star 2.0
  • Standard
    ▪️ Advance Power Walk-in for Generator
    ▪️ Backfeed Protection with Contactor
    ▪️ Burn-in Test without Load Bank
    ▪️ Cold Start Function
    ▪️ Synchronized Multiple Bus (SMB)
    ▪️ Frequency Conversion
    ▪️ Battery Shunt Trip
    ▪️ Auxiliary Power 48 Vdc for Shunt Trip
    ▪️ Failure Prediction
  • Optional
    ▪️ Grid Interactive
    ▪️ Software Integration with Delta Lithium Battery BMS
    ▪️ DC Battery Ground Fault Detector
    ▪️ Integrated Battery Switch Cabinet
    ▪️ IR Scan Window