Delta DPH Series 20-80/50-200 kVA

Features and Benefits

  • Low Total Cost of Ownership
    • AC-AC efficiency up to 96.5% and Eco mode to 99% optimize energy costs
    • Activate Green mode with a load aggregation function to boost system efficiency
    • Remarkable power density of 50 kW per module in a 3U height (20 kW / 2U height) offering best space utilization
    • Unleash the on-site full-load and full-battery test. No need for load banks, no set-ups—streamline process and cut costs effectively
  • Maximum Uptime
    • Redundant components and dual CAN bus deliver highest system availability and thwart single point of failure
    • Power and control modules self-synchronize to prevent downtime from control module failure
    • Fully modularized design and hot swappable STS module, power module and controller card ensure minimize Mean Time To Repair (MTTR)
    • Integrated manual bypass eliminates maintenance-related downtime
    • Pre-warning of key components aging reduces downtime risk (optional)
  • Easy Management
    • Precisely meet your power backup needs now and unlock the ability to effortlessly scale up as your business flourishes
    • Color 10’’ touchscreen provides easy access to UPS information and streamlined operation
    • Intuitive LCD integrated UPS system, inbuilt battery and environment information visible and easy to manage
    • Built-in USB port provides effortless connectivity to over 10,000 data logs for event diagnosis

Available to Order

Models

  • DPH-80K-FR
  • DPH-200K-FR

Overview

Introduction

Experience the internationally celebrated Delta Modulon DPH Series UPS — a true standout for data centers worldwide. Renowned for its world-leading power module density and unparalleled reliability, this UPS has earned broad recognition in recent years.

Introducing an ingenious 80 kVA solution with an integrated battery, thoughtfully nested within a 42U rack. Need more power? Explore 200 kVA options as your business surges forward. You are ready to adapt as your business progresses!

Specifications

Power Rating

DPH-80K-FR

  • 20/ 40/ 60/ 80 kVA
  • 20/ 40/ 60/ 80 kW

DPH-200K-FR

  • 50/ 100/ 150/ 200/ 200+50 (as redundant) kVA
  • 50/ 100/ 150/ 200/ 200+50 (as redundant) kW
  • 80 kW
  • Up to 8 units

Nominal Voltage

  • 380/ 400/ 415 Vac, 3P4W+PE

Voltage Range

  • 176-276/ 305-477 Vac (full load)
  • 132-176/ 229-305 Vac (de-rated 70% load)

Frequency

  • 40-70 Hz

Total Harmonic Distortion (THDi)

  • < 3 %

Power Factor

  • > 0.99 (full load)

Nominal Voltage

  • 380/ 400/ 415 Vac, 3P4W+PE

Voltage Regulation

  • ±1% (static)

Frequency

  • 50/60 ± 0.05 Hz

Total Harmonic Distortion (THDv)

  • ≤ 1% (linear load), ≤ 4% (non-linear load)(1)

Power Factor

  • 1.0

Overload Capability

  • ≤ 125%: 10 minutes; ≤ 150%: 1 minutes; > 150%: 1 sec

Current Crest Ratio

  • 3:1

Online Mode

  • Up to 96.5%

ECO Mode

  • Up to 99%

Battery Type

  • VRLA/ Vented lead-acid/ Lithium-ion battery

Nominal Voltage

  • ±240 Vdc

Quantity

DPH-80K-FR

  • 40 pcs

DPH-200K-FR

  • 30(2)-46 pcs (configurable)

Maximum Charge Current

DPH-80K-FR

  • 32 A

DPH-200K-FR

  • 75 A

Internal Battery

DPH-80K-FR

  • Optional, up to 5 strings

DPH-200K-FR

  • N/A

External Battery Cabinet (Optional)

  • Parallel to 4 cabinets(3)

Display

  • 10’’ Color Touch Screen

Port

  • Modbus (RS-485) port, REPO, EMS/Console (RJ45), BMS (RS-485), Ethernet port x1, Input dry contact x4, Output dry contact x6, External battery temperature detection x4, External switch/breaker status dry contact x4

Protocols

  • SNMP, Modbus RTU, Modbus TCP/IP, HTTP(S), SNTP, SMTP, Syslog, BOOTP, DHCP

Dimensions (W x D x H)

  • 600 x 1109 x 2000 mm

Net Weight

UPS System (DPH-80K-FR)

  • 269 kg

UPS System (DPH-200K-FR)

  • 275 kg

Per Power Module (DPH-80K-FR)

  • 18 kg

Per Power Module (DPH-200K-FR)

  • 36.9 kg

Per Battery Module(3)

  • 32.6 kg

Operating Temperature

  • 0 to 40°C

Humidity

  • 0-95% (non-condensing)

Audible Noise

DPH-80K-FR

  • < 65 dBA

DPH-200K-FR

  • < 75 dBA

Altitude

  • 0-1,000 m

Storage Temperature

  • -20 to +70°C

Ingress Protection

  • IP20

Safety

  • CE, BSMI, RCM

EMC

  • IEC 62040-2

Performance

  • IEC 62040-3

Sustainability

  • RoHS, REACH

Burn-in Test without Load Bank

  • Standard

Cold Start Function

  • Standard

Frequency Conversion

  • Standard

Failure Prediction

  • Standard

Software Integration with Delta Lithium Battery BMS

  • Standard