Features and Benefits

  • Supports up to 4 managed Ethernet switch ports (fiber available with some optional network modules)
  • 8/16-port RS-232/422/485 serial interface
  • Supports DNP3 and Modbus protocols
  • Ethernet redundancy with Turbo Ring/Chain and RSTP/STP supported
  • Real COM/TTY drivers for Windows and Linux
  • IEC 61850-3, IEEE 1613 (power substations) compliant
  • IEEE 1588v2 and IRIG-B time synchronization functions
  • Supports IEC 61850 MMS protocol
  • Security features based on IEC 62443/NERC CIP
  • -40 to 85°C wide operating temperature

Models

  • NPort S9650I-8-2HV-SSC-T
  • NPort S9650I-8B-2HV-IRIG-T
  • NPort S9650I-16-2HV-E-T
  • NPort S9650I-16B-2HV-IRIG-T
  • NPort S9650I-16F-2HV-E-T
  • NPort S9650I-16-2HV-MSC-T
  • NPort S9650I-16-2HV-SSC-T
  • NPort S9650I-8-2HV-E-T
  • NPort S9650I-16F-2HV-MSC-T
  • NPort S9650I-8F-2HV-SSC-T
  • NPort S9650I-8-2HV-MSC-T
  • NPort S9650I-16F-2HV-SSC-T
  • NPort S9650I-8F-2HV-E-T
  • NPort S9650I-8F-2HV-MSC-T

Overview

How to Buy

Click “WhatsApp Us” or “Get a Quote” above to buy NPort S9650I from APulsar Technologies, MOXA official distributor.

Purchase walk-in from our office in Petaling Jaya, or order online and enjoy fast delivery across Kuala Lumpur and the entire Malaysia.

Introduction

The NPort S9650I Series 8/16-port RS-232/422/485 device servers, which come with a built-in full-function managed Ethernet switch, are designed specifically for the harsh environmental conditions found in electrical substations. With both fiber and wired Ethernet ports supported, the combination of a device server and Ethernet switch gives users the ability to easily install, manage, and maintain the NPort S9650I itself, as well as attached serial devices.

Electromagnetic Compatibility for Harsh Substation Environments

The NPort S9650I Series supports a high level of surge protection to prevent damage from the types of power surges and EMI one finds in electrical substations and industrial automation applications. Combined with a -40 to 85°C operating temperature range and galvanized steel housing, the NPort S9650I is suitable for a wide range of industrial environments.

Another plus is the NPort S9650I’s dual power supplies, which provide both redundancy, as well as a wide range of voltage inputs. The WV models accept a 24/48 VDC power input (ranging from 18 to 72 VDC), and the HV models accept a power input of 88 to 300 VDC and 85 to 264 VAC.

Power SCADA With IEC 61850 MMS for Easy Maintenance

The current trend in power SCADA applications is to control and monitor both IT devices (switches, routers, etc.) and IEDs (sensors, actuators, etc.) with the MMS protocol. Contrast this with the more traditional management approach of using SNMP for IT devices and MMS for IEDs. In fact, SIs may even need to manage a variety of legacy devices that use proprietary communications protocols.

The NPort S9650I device servers are the world’s first device servers to integrate MMS into an IT-type device designed specifically for power SCADA applications. The NPort S9650I even supports using MMS to monitor serial communications between the S9650I and legacy devices.

Supports Modbus/DNP3 Protocol Gateway

The NPort S9650I Series provides maximum flexibility for integrating industrial Modbus/DNP3 networks of all types and sizes. The NPort S9650I is designed to integrate Modbus TCP, ASCII, and RTU devices in almost any master/slave combination, including simultaneous serial and Ethernet masters.

The NPort S9650I device servers also support protocol conversion between DNP3 serial and DNP3 IP, and all models are ruggedly constructed to ensure reliable operation.

Cybersecurity Features Based on IEC 62443/NERC CIP

The NPort S9650I Series has security features based on IEC 62443/NERC CIP to provide a high level of cybersecurity. Protecting mission-critical networks from cyberattacks is a high priority for industrial automation applications, which can suffer large losses due to extended network downtime.

Supports IEEE 1588v2 and IRIG-B Time Synchronization Functions

The NPort S9650I Series, which has a modular design that supports IEEE 1588v2 and IRIG-B time synchronization, is able to interconnect and synchronize multiple types of intelligent electronic devices (IEDs) that use different communication protocols. The time source is provided via IEEE 1588v2 and converted to IRIG-B for distribution to the IEDs via the serial ports or via a dedicated IRIG-B BNC connector.

Ring Redundancy at the Device Level

Device-level communication networks for industrial automation are very critical since they are used to control and monitor device processes. The reliability of these communications depends on ring redundancy at the device level, which is designed to provide fast network fault detection and reconfiguration to support the most demanding control applications. The NPort S9650I Series integrates a full-function NPort device server with an industrial switch to carry serial and Ethernet devices at the same time. In addition, the NPort S9650I Series can achieve ring redundancy with standard STP/RSTP and Moxa’s proprietary Turbo Ring or Turbo Chain 2 redundancy protocols. This all-in-one design can be used to optimize and simplify your device network and enhance reliability.

Specifications

Input/Output Interface

Alarm Contact Channels

  • Resistive load: 1 A @ 24 VDC

10/100BaseT(X) Ports (RJ45 connector)

  • NPort S9650I-E Series: 4 RJ45 ports
  • NPort S9650I-MSC Series: 2 RJ45 ports
  • NPort S9650I-SSC Series: 2 RJ45 ports
  • NPort S9650I-IRIG Series: 2 RJ45 ports

100BaseFX Ports (multi-mode SC connector)

  •  NPort S9650I-MSC Series: 2 multi-mode SC ports

100BaseFX Ports (single-mode SC connector)

  • NPort S9650I-SSC Series: 2 single-mode SC ports

Magnetic Isolation Protection

  • 1.5 kV (built-in)

Optical Fiber

IGMP Groups

  • 256

Max. No. of VLANs

  • 64

Priority Queues

  • 4

VLAN ID Range

  • VID 1 to 4094

Configuration Options

  • Web Console (HTTP/HTTPS), Windows Utility, Device Search Utility (DSU), MCC Tool, Command Line Interface (CLI) through Serial/Telnet/SSH

Management

  • DHCP Client, DHCP Option 82, HTTP, IEC 61850 MMS, IPv4, LLDP, Port Mirror, RARP, RMON, SMTP, SNMPv1/v2c/v3, Syslog, Telnet, TFTP, Web Console

Filter

  •  GMRP, GVRP, IGMP v1/v2

Windows Real COM Drivers

  • Windows 95/98/ME/NT/2000, Windows XP/2003/Vista/2008/7/8/8.1/10 (x86/x64), Windows 2008 R2/2012/2012 R2/2016/2019 (x64), Windows Embedded CE 5.0/6.0, Windows XP Embedded

Linux Real TTY Drivers

  • Kernel versions: 2.4.x, 2.6.x, 3.x, 4.x, and 5.x

Fixed TTY Drivers

  • SCO UNIX, SCO OpenServer, UnixWare 7, QNX 4.25, QNX 6, Solaris 10, FreeBSD, AIX 5.x, HP-UX 11i, Mac OS X

Android API

  • Android 3.1.x and later

Industrial Protocols

  • Modbus TCP Server (Slave), DNP3 TCP Outstation

Time Management

  • NTP Server/Client, SNTP, IEEE 1588v2 PTP (hardware-based), IRIG-B

MIB

  • Bridge MIB, Device Settings MIB, Ethernet-like MIB, MIB-II, P-BRIDGE MIB, Q-BRIDGE MIB, RFC1213, RFC1317, RMON MIB Groups 1, 2, 3, 9, RSTP MIB

Redundancy Protocols

  • RSTP, Turbo Chain, Turbo Ring v1, Turbo Ring v2

Security

  • HTTPS/SSL, Local Account Accessibility, TACACS+, RADIUS, SSH

PWM/PPS Output, BNC Connector

  • NPort S9650I-IRIG Series: 1

PWM/PPS Output, DB9 Female

  • NPort S9650I-8B-2HV-IRIG-T: 8
  • NPort S9650I-16B-2HV-IRIG-T: 16

PWM Input, BNC Connector

  • NPort S9650I-IRIG Series: 1

Connector

  • NPort S9650I-8/-16 Series: DB9 male
  • NPort S9650I-8B/-16B Series: DB9 female
  • NPort S9650I-8F/-16F Series: Multi-mode fiber ST connector

No. of Ports

  • 8 or 16

Serial Standards

  • RS-232, RS-422, RS-485

Operation Modes

  • Real COM mode, RFC2217 mode, TCP Client mode, TCP Server mode, UDP mode, Modbus mode, DNP3 mode, DNP3 Raw Socket mode, Disabled

Baudrate

  • 50 bps to 921.6 kbps (supports non-standard baudrates)

Data Bits

  • 5, 6, 7, 8

Stop Bits

  • 1, 1.5, 2

Parity

  • None, Even, Odd, Space, Mark

Flow Control

  • None, RTS/CTS, XON/XOFF

Isolation

  • 2 kV

Surge

  • 4 kV

RS-485 Data Direction Control

  • ADDC® (automatic data direction control)

Pull High/Low Resistor for RS-485

  • 1 kilo-ohm, 150 kilo-ohms

Terminator for RS-485

  • 120 ohms

Console Port

  • RS-232 (TxD, RxD, GND), 10-pin RJ45 (19200, n, 8, 1)

RS-232

  • NPort S9650I-IRIG Series: TxD, RxD, RTS, CTS, DTR/+IRIG-B, DSR, DCD, GND
  • NPort S9650I Series: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND

RS-422

  •  NPort S9650I-IRIG Series: TxD+, TxD-, RxD+, RxD-, GND, +IRIG-B
  • NPort S9650I Series: Tx+, Tx-, Rx+, Rx-

RS-485-4w

  • Tx+, Tx-, Rx+, Rx-, GND

RS-485-2w

  • NPort S9650I-IRIG Series: Data+, Data-, GND, +IRIG-B
  • NPort S9650I Series: Data+, Data-, GND

Ethernet Interface

  • Turbo Ring, Master, Coupler, Reserved

Max. No. of Client Connections

  • 32

Max. No. of Server Connections

  • 16

Max. No. of Master Connections

  • 16

Max. No. of Outstation Connections

  • 32

Automatic Reboot Trigger

  • Built-in WDT

Alert Tools

  • Built-in buzzer and RTC (real-time clock)

No. of Power Inputs

  • 2

Reverse Polarity Protection

  • Supported

Input Current

  • 0.65 A @ 100 VAC, 0.47A @ 100 VDC

Input Voltage

  • 110/220 VAC/VDC (100 to 240 VAC, 100 to 250 VDC)

Housing

  • Metal

Installation

  • 19-inch rack mounting

Dimensions

  • 457 x 32 x 330 mm (18 x 1.25 x 12.99 in)

Weight

  • Product only: 5.15 kg (11.35 lb)

Operating Temperature

  •  -40 to 85°C (-40 to 185°F)

Storage Temperature (package included)

  • -40 to 85°C (-40 to 185°F)

Ambient Relative Humidity

  • 5 to 95% (non-condensing)

EMC

  • EN 61000-6-2/-6-4

EMI

  • CISPR 32, FCC Part 15B Class A

EMS

  • IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
  • IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
  • IEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kV
  • IEC 61000-4-5 Surge: Power: 4 kV; Signal: 4 kV
  • IEC 61000-4-6 CS: 150 kHz to 80 MHz: 10 V/m; Signal: 10 V/m
  • IEC 61000-4-8 PFMF
  • IEC 61000-4-11

Environmental Testing

  • IEC 60068-2-2
  • IEC 60068-2-14

Power Substation

  • IEC 61850-3, IEEE 1613

Safety

  • EN 61010-2-201, UL 61010-2-201

Shock

  • IEC 60068-2-27

Vibration

  • IEC 60068-2-6, IEC 60068-2-64

Green Product

  • RoHS, CRoHS, WEEE

Time

  • NPort S9650I-8-2HV-E-T: 224,670 hrs
  • NPort S9650I-8-2HV-MSC-T: 220,944 hrs
  • NPort S9650I-8-2HV-SSC-T: 220,944 hrs
  • NPort S9650I-8B-2HV-IRIG-T: 213,025 hrs
  • NPort S9650I-8F-2HV-E-T: 311,734 hrs
  • NPort S9650I-8F-2HV-MSC-T: 304,587 hrs
  • NPort S9650I-8F-2HV-SSC-T: 304,587 hrs
  • NPort S9650I-16-2HV-E-T: 158,816 hrs
  • NPort S9650I-16-2HV-MSC-T: 156,949 hrs
  • NPort S9650I-16-2HV-SSC-T: 156,949 hrs
  • NPort S9650I-16B-2HV-IRIG-T: 157,770 hrs
  • NPort S9650I-16F-2HV-E-T: 261,817 hrs
  • NPort S9650I-16F-2HV-MSC-T: 256,761 hrs
  • NPort S9650I-16F-2HV-SSC-T: 256,761 hrs

Standards

  • Telcordia SR332