Transio A52/A53 Series

Features and Benefits

  • Automatic Data Direction Control (ADDC) RS-485 data control
  • Automatic baudrate detection
  • RS-422 hardware flow control: CTS, RTS signals
  • LED indicators for power and signal status
  • RS-485 multidrop operation, up to 32 nodes
  • 2 kV isolation protection (A53)
  • Built-in 120-ohm termination resistors

Models

  • A53-DB25F w/ Adapter
  • A52-DB25F w/ Adapter
  • A53-DB25F w/o Adapter
  • A53-DB9F w/ Adapter
  • A52-DB9F w/o Adapter
  • A52-DB25F w/o Adapter
  • A52-DB9F w/ Adapter
  • A53-DB9F w/o Adapter

Overview

How to Buy

Click “WhatsApp Us” or “Get a Quote” above to buy TRC-190 from APulsar Technologies, MOXA official distributor.

Purchase walk-in from our office in Petaling Jaya, or order online and enjoy fast delivery across Kuala Lumpur and the entire Malaysia.

Introduction

The A52 and A53 are general RS-232 to RS-422/485 converters designed for users who need to extend RS-232 transmission distance and increase networking capability.

Specifications

Serial Interface

Connector

  • 10-pin RJ45

Flow Control

  • RTS/CTS

Isolation

  • A53 Series: 2 kV

No. of Ports

  • 2

RS-485 Data Direction Control

  • ADDC (automatic data direction control)

Serial Standards

  • RS-232
  • RS-422
  • RS-485

RS-232

  • TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND

RS-422

  • Tx+, Tx-, Rx+, Rx-, RTS+, RTS-, CTS+, CTS-, GND

RS-485-4w

  • Tx+, Tx-, Rx+, Rx-, GND

RS-485-2w

  • Data+, Data-, GND

Input Current

  • A52 Series: 170 mA @ 9 VDC
  • A53 Series: 195 mA @ 9 VDC

Input Voltage

  • 9 to 30 VDC

No. of Power Inputs

  • 1

Overload Current Protection

  • Supported

Power Consumption

  • A52 Series: 170 mA @ 9 VDC
  • A53 Series: 195 mA @ 9 VDC

Source of Input Power

  • Power input jack

Housing

  • Plastic

IP Rating

  • IP30

Dimensions

  • 90 x 60 x 21 mm (3.54 x 2.36 x 0.83 in)

Weight

  • 85 g (0.19 lb)

Installation

  • Desktop

Operating Temperature

  • 0 to 55°C (32 to 131°F)

Storage Temperature (package included)

  • -20 to 75°C (-4 to 167°F)

Ambient Relative Humidity

  • 5 to 95% (non-condensing)

EMC

  • EN 55032/35

EMI

  • CISPR 32, FCC Part 15B Class A

EMS

  • IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
  • IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m
  • IEC 61000-4-4 EFT: Power: 1 kV; Signal: 0.5 kV
  • IEC 61000-4-5 Surge: Power: 1 kV
  • IEC 61000-4-6 CS: 150 kHz to 80 MHz: 3 V/m; Signal: 3 V/m
  • IEC 61000-4-8 PFMF

Environmental Testing

  • IEC 60068-2-1
  • IEC 60068-2-14
  • IEC 60068-2-2
  • IEC 60068-2-3

Vibration

  • IEC 60068-2-6

Time

  • 1,870,854 hrs

Standards

  • Telcordia (Bellcore), GB

Warranty Period

  • 5 years