NPort 6400/6600 Series

Features and Benefits

  • LCD panel for easy IP address configuration (standard temp. models)
  • Secure operation modes for Real COM, TCP Server, TCP Client, Pair Connection, Terminal, and Reverse Terminal
  • Nonstandard baudrates supported with high precision
  • Port buffers for storing serial data when the Ethernet is offline
  • Supports IPv6
  • Ethernet redundancy (STP/RSTP/Turbo Ring) with network module
  • Generic serial commands supported in Command-by-Command mode

Models

  • NPort 6610-16-48V
  • NPort 6650-32-48V
  • NPort 6610-32
  • NPort 6650-32-HV-T
  • NPort 6610-16
  • NPort 6650-32
  • NPort 6610-8
  • NPort 6650-16-T
  • NPort 6450-T
  • NPort 6650-16-48V
  • NPort 6450
  • NPort 6650-16
  • NPort 6610-8-48
  • NPort 6650-16-HV-T
  • NPort 6650-8
  • NPort 6650-8-HV-T
  • NPort 6610-32-48V
  • NPort 6650-8-48V
  • NPort 6650-8-T

Overview

How to Buy

Click “WhatsApp Us” or “Get a Quote” above to buy NPort 6400/6600 from APulsar Technologies, MOXA official distributor.

Purchase walk-in from our office in Petaling Jaya, or order online and enjoy fast delivery across Kuala Lumpur and the entire Malaysia.

Introduction

The NPort® 6000 is a terminal server that uses the TLS and SSH protocols to transmit encrypted serial data over Ethernet. Up to 32 serial devices of any type can be connected to the NPort® 6000, using the same IP address. The Ethernet port can be configured for a normal or secure TCP/IP connection. The NPort® 6000 secure device servers are the right choice for applications that use large numbers of serial devices packed into a small space. Security breaches are intolerable and the NPort® 6000 Series ensures data transmission integrity with support for AES encryption algorithm. Serial devices of any type can be connected to the NPort® 6000, and each serial port on the NPort® 6000 can be configured independently for RS-232, RS-422, or RS-485 transmission.

No Data Loss If Ethernet Connection Fails

The NPort® 6000 is a reliable device server that provides users with secure serial-to-Ethernet data transmission and a customer-oriented hardware design. If the Ethernet connection fails, the NPort® 6000 will queue all serial data in its internal 64 KB port buffer. When the Ethernet connection is re-established, the NPort® 6000 will immediately release all data in the buffer in the order that it was received. Users can increase the port buffer size by installing an SD card.

LCD Panel Makes Configuration Easy

The NPort® 6600 has a built-in LCD panel for configuration. The panel displays the server name, serial number, and IP address, and any of the device server’s configuration parameters, such as IP address, netmask, and gateway address, can be updated easily and quickly.

Note: The LCD panel is only available with standard-temperature models.

Adjustable Resistor Values for RS-485 Communication

The NPort® 6600 provides adjustable termination, pull high, and pull low resistors for RS-485 communication. In some critical environments, termination resistors may be needed to prevent the reflection of serial signals, and the pull high and pull low resistors may need adjusting to maintain the integrity of the electrical signal. Since no set of resistor values works for every environment, the NPort® 6600 allows manual adjustment of the resistor values for each serial port using built-in DIP switches.

Specifications

Memory

SD Slot

  • Up to 32 GB (SD 2.0 compatible)

Alarm Contact Channels

  • Resistive load: 1 A @ 24 VDC

10/100BaseT(X) Ports (RJ45 connector)

  • 1
  • Auto MDI/MDI-X connection

Magnetic Isolation Protection

  • 1.5 kV (built-in)

Compatible Modules

  • NM Series expansion modules for optional extension of RJ45 and fiber Ethernet ports

Optical Fiber

100BaseFX
Multi-Mode Single-Mode
Fiber Cable Type OM1 50/125 µm G.652
800 MHz x km
Typical Distance 4 km 5 km 40 km
Wavelength Typical (nm) 1300 1310
TX Range (nm) 1260 to 1360 1280 to 1340
RX Range (nm) 1100 to 1600 1100 to 1600
Optical Power TX Range (dBm) -10 to -20 0 to -5
RX Range (dBm) -3 to -32 -3 to -34
Link Budget (dB) 12 29
Dispersion Penalty (dB) 3 1
Note: When connecting a single-mode fiber transceiver, we recommend using an attenuator to prevent damage caused by excessive optical power.
Note: Compute the “typical distance” of a specific fiber transceiver as follows: Link budget (dB) > dispersion penalty (dB) + total link loss (dB).

Configuration Options

  • Serial Console
  • Windows Utility
  • Device Search Utility (DSU)
  • MCC Tool
  • Telnet/SSH Console
  • Web Console (HTTP/HTTPS)

Management

  • DHCP Client
  • IPv4/IPv6
  • SMTP
  • SNMPv1/v2c/v3
  • Telnet
  • DNS
  • HTTP
  • ARP
  • BOOTP
  • UDP
  • TCP/IP
  • ICMP
  • LLDP
  • PPPOE
  • SNTP

Windows Real COM Drivers

  • Windows 11, 10, 8.1, 8, 7, Vista, XP, ME, 98, and 95
  • Windows Server 2022, 2019, 2016, 2012 R2, 2012, 2008 R2, 2008, 2003, 2000, and NT
  • Windows Embedded CE 6.0 and 5.0, Windows XP Embedded

Linux Real TTY Drivers

  • Kernel versions 6.x, 5.x, 4.x, 3.x, 2.6.x, and 2.4.x

Fixed TTY Drivers

  • macOS versions: 14, 13, 12, 11, and 10.1x
  • SCO UNIX, SCO OpenServer, UnixWare 7, QNX 4.25, QNX 6.x, Solaris 10, FreeBSD, AIX 5.x, HP-UX 11i, Mac OS X

Arm®-based Platform Support

  • Windows 11
  • Linux Kernel 6.x, 5.x, and 4.x
  • macOS 14, 13, 12, and 11

Virtual Machine

  • VMWare ESXi (Windows 11/10)
  • VMware Fusion (Windows on macOS 14, 13, 12, 11, and 10.1x)
  • Parallels Desktop (Windows on macOS 14, 13, 12, 11, and 10.1x)

Android API

  • Android 3.1.x and later

MIB

  • MIB-II

Time Management

  • SNTP Client

Unicast Routing

  • RIPV1/V2
  • Static Route

Authentication

  • Local database
  • RADIUS
  • TACACS+

Encryption

  • HTTPS
  • AES-128
  • AES-256
  • HMAC
  • RSA-1024
  • SHA-1
  • SHA-256
  • SHA-384

Security Protocols

  • HTTPS (TLS 1.2)
  • SNMPv3
  • SSHv2

Connector

  • NPort 6600 models: 8-pin RJ45
  • NPort 6450 models: DB9 male

No. of Ports

  • NPort 6450 models: 4
  • NPort 6600-8 models: 8
  • NPort 6600-16 models: 16
  • NPort 6600-32 models: 32

Serial Standards

  • NPort 6610 models: RS-232
  • NPort 6450/6650 models: RS-232/422/485

Secure Operation Modes

  • Reverse SSH
  • Secure Pair Connection
  • Secure Real COM
  • Secure TCP Client
  • Secure TCP Server
  • SSH

Standard Operation Modes

  • Disabled
  • Ethernet Modem
  • Pair Connection
  • PPP
  • Printer
  • Real COM
  • Reverse Telnet
  • RFC2217
  • TCP Client
  • TCP Server
  • Terminal
  • UDP

Baudrate

  • 50 bps to 921.6 kbps (supports non-standard baudrates)

Console Port

  • NPort 6600 models: RS-232 (TxD, RxD, GND), 8-pin RJ45 (19200, n, 8, 1)

Data Bits

  • 5, 6, 7, 8

Stop Bits

  • 1, 1.5, 2

Parity

  • None
  • Even
  • Odd
  • Space
  • Mark

Flow Control

  • RTS/CTS
  • DTR/DSR
  • XON/XOFF

Pull High/Low Resistor for RS-485

  • NPort 6450/6650 models: 1 kilo-ohm, 150 kilo-ohms

RS-485 Data Direction Control

  • NPort 6450/6650 models: Automatic Data Direction Control (ADDC)

Terminator for RS-485

  • NPort 6450/6650 models: 120 ohms

RS-232

  • TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND

RS-422

  • Tx+, Tx-, Rx+, Rx-, GND

RS-485-4w

  • Tx+, Tx-, Rx+, Rx-, GND

RS-485-2w

  • Data+, Data-, GND

Input Current

  • NPort 6450 models: 730 mA @ 12 VDC
  • NPort 6600 models:
  • DC models: 293 mA @ 48 VDC, 200 mA @ 88 VDC
  • AC models: 140 mA @ 100 VAC (8 ports), 192 mA @ 100 VAC (16 ports), 285 mA @ 100 VAC (32 ports)

Input Voltage

  • NPort 6450 models: 12 to 48 VDC
  • NPort 6600 models:
  • AC models: 100 to 240 VAC
  • DC -48V Models: ±48 VDC (20 to 72 VDC, -20 to -72 VDC)
  • DC -HV Models: 110 VDC (88 to 300 VDC)

Automatic Reboot Trigger

  • Built-in WDT

Alert Tools

  • Built-in buzzer and RTC (real-time clock)

Housing

  • Metal

Installation

  • NPort 6450 models: Desktop, DIN-rail mounting, Wall mounting
  • NPort 6600 models: Rack mounting (with optional kit)

Dimensions (with ears)

  • NPort 6450 models: 181 x 103 x 35 mm (7.13 x 4.06 x 1.38 in)
  • NPort 6600 models: 480 x 195 x 44 mm (18.9 x 7.68 x 1.73 in)

Dimensions (without ears)

  • NPort 6450 models: 158 x 103 x 35 mm (6.22 x 4.06 x 1.38 in)
  • NPort 6600 models: 440 x 195 x 44 mm (17.32 x 7.68 x 1.73 in)

Weight

  • NPort 6450 models: 1,020 g (2.25 lb)
  • NPort 6600-8 models: 3,460 g (7.63 lb)
  • NPort 6600-16 models: 3,580 g (7.89 lb)
  • NPort 6600-32 models: 3,600 g (7.94 lb)

Interactive Interface

  • LCD panel display (non-T models only)
  • Push buttons for configuration (non-T models only)

Operating Temperature

  • Standard models: 0 to 55°C (32 to 131°F)
  • -HV models: -40 to 85°C (-40 to 185°F)
  • All other -T models: -40 to 75°C (-40 to 167°F)

Storage Temperature (package included)

  • Standard models: -40 to 75°C (-40 to 167°F)
  • -HV models: -40 to 85°C (-40 to 185°F)
  • All other -T models: -40 to 75°C (-40 to 167°F)

Ambient Relative Humidity

  • 5 to 95% (non-condensing)

EMC

  • EN 55032/35

EMI

  • CISPR 32, FCC Part 15B Class A

EMS

  • NPort 6450 models:
    IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
    IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m
    IEC 61000-4-4 EFT: Power: 1 kV; Signal: 0.5 kV
    IEC 61000-4-5 Surge: Power: 1 kV
    IEC 61000-4-6 CS: 150 kHz to 80 MHz: 3 V/m; Signal: 3 V/m
    IEC 61000-4-8 PFMF
    IEC 61000-4-11
  • NPort 6600 models (except -48V/-HV models):
    IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
    IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m
    IEC 61000-4-4 EFT: Power 1 kV; Signal 0.5 kV
    IEC 61000-4-5 Surge: Power: 2 kV
    IEC 61000-4-6 CS: 150 kHz to 80 MHz: 3 V/m; Signal: 3 V/m
    IEC 61000-4-8 PFMF
    IEC 61000-4-11
  • NPort 6600-48V models:
    IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
    IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m
    IEC 61000-4-4 EFT: Power: 1 kV; Signal: 0.5 kV
    IEC 61000-4-5 Surge: Power: 1 kV
    IEC 61000-4-6 CS: 150 kHz to 80 MHz: 3 V/m; Signal: 3 V/m
    IEC 61000-4-8 PFMF
  • NPort 6650-HV models:
    IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
    IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m
    IEC 61000-4-4 EFT: Power: 4 kV; Signal: 2 kV
    IEC 61000-4-5 Surge: Power: 2 kV
    IEC 61000-4-6 CS: 150 kHz to 80 MHz: 3 V/m; Signal: 3 V/m
    IEC 61000-4-8 PFMF

Safety

  • UL 60950-1

Traffic Control

  • NEMA TS2

Vibration

  • IEC 60068-2-6

Freefall

  • IEC 60068-2-34

Green Product

  • RoHS, CRoHS, WEEE

Time

  • NPort 6450 models: 850,905 hrs
  • NPort 6610-8 models: 135,891 hrs
  • NPort 6610-16 models: 102,373 hrs
  • NPort 6610-32 models: 68,707 hrs
  • NPort 6650-8 models: 636,600 hrs
  • NPort 6650-16 models: 439,673 hrs
  • NPort 6650-32 models: 310,078 hrs
  • NPort 6650-8-HV-T: 501,171 hrs
  • NPort 6650-16-HV-T: 380,006 hrs
  • NPort 6650-32-HV-T: 290,914 hrs

Standards

  • NPort 6450 models: Telcordia (Bellcore) Standard TR/SR
  • NPort 6600 models: Telcordia (Bellcore) Standard

Warranty Period

  • 5 years