CN2600 Series

Features and Benefits

  • LCD panel for easy IP address configuration (excluding wide-temperature range models)
  • Dual-LAN cards with two independent MAC addresses and IP addresses
  • Redundant COM function available when both LANs are active
  • Dual-host redundancy can be used to add a backup PC to your system
  • Dual-AC-power inputs (for AC models only)
  • Real COM and TTY drivers for Windows, Linux, and macOS
  • Universal high-voltage range: 100 to 240 VAC or 88 to 300 VDC

Models

  • CN2650-8-2AC
  • CN2610-8
  • CN2610-16-2AC
  • CN2650I-16-2AC
  • CN2650I-16-HV-T
  • CN2650-8-2AC-T
  • CN2650-8
  • CN2650I-16
  • CN2650I-8
  • CN2650I-8-2AC
  • CN2610-16
  • CN2650-16-2AC-T
  • CN2650-16-2AC
  • CN2610-8-2AC
  • CN2650I-8-HV-T
  • CN2650-16

Overview

How to Buy

Click “WhatsApp Us” or “Get a Quote” above to buy CN2600 from APulsar Technologies, MOXA official distributor.

Purchase walk-in from our office in Petaling Jaya, or order online and enjoy fast delivery across Kuala Lumpur and the entire Malaysia.

Introduction

Redundancy is an important issue for industrial networks, and various types of solutions have been developed to provide alternative network paths when equipment or software failures occur. “Watchdog” hardware is installed to utilize redundant hardware, and a “Token”- switching software mechanism is applied. The CN2600 terminal server uses its built-in Dual-LAN ports to implement a “Redundant COM” mode that keeps your applications running uninterrupted.

Dual-LAN Redundancy

The CN2600 has two separate LAN ports that can be connected to separate LAN networks. Dual-LAN redundancy involves setting up two separate physical networks to connect the PC host with the CN2600 (the PC host also requires two LAN cards). If one connection fails, the PC host can still communicate with your serial devices over the alternative LAN connection.

Redundant COM

Moxa offers “Redundant COM,” an easy-to-use application to provide an alternative solution for network redundancy. When the CN2600 receives a data packet from a connected device, two identical data packets are sent over two independent LAN connections to prevent lost data packets if one LAN connection becomes unavailable. The CN2600 software is programmed to automatically discard duplicate data packets.

Dual-host Redundancy

The CN2600’s dual-LAN cards can also be used to set up “dual-host” redundancy. In this case, both networks (LAN A and LAN B in the figure) are connected to two different hosts. If either of the two hosts shuts down unexpectedly, the other host will still be able to communicate with serial devices connected to the CN2600.

Dual-AC Model Supported

Dual-power redundancy uses two power inputs and redundant internal power supplies to ensure that all of the CN2600’s functions will be available, even in the event of power circuit failures.

Specifications

Ethernet Interface

10/100BaseT(X) Ports (RJ45 connector)

  • 2

Magnetic Isolation Protection

  • 1.5 kV (built-in)

Configuration Options

  • CN2610-8/CN2610-16 models:
  • Serial Console, Telnet Console, Windows Utility, Device Search Utility (DSU)
  • CN2650-8/CN2650-16/CN2600-2AC models:
  • Serial Console, Telnet Console, Windows Utility, Device Search Utility (DSU), Web console (HTTP/HTTPS)

Management

  • ARP
  • BOOTP
  • DDNS
  • DHCP Client
  • DNS
  • HTTP
  • IPv4
  • SMTP
  • SNMPv1/v2c/v3
  • TCP/IP
  • Telnet
  • UDP
  • ICMP
  • SLIP

MIB

  • MIB-II

Security

  • HTTPS/SSL
  • RADIUS
  • SSH
  • PAP
  • CHAP

Unicast Routing

  • RIPV1/V2
  • Static Route

Windows Real COM Drivers

  • Windows 11, 10, 8.1, 8, 7, Vista, XP, ME, 98 and 95
  • Windows Server 2022, 2019, 2016, 2012 R2, 2012, 2008 R2, 2008, 2003, 2000 and NT
  • Windows Embedded CE 5.0 and 6.0, Windows XP Embedded

Linux Real TTY Drivers

  • Kernel versions: 6.x, 5.x, 4.x, 3.x, 2.6.x and 2.4.x

Fixed TTY Drivers

  • macOS versions: 14, 13, 12, 11 and 10.1x
  • SCO UNIX, SCO OpenServer, UnixWare 7, QNX 4.25, QNX 6, Solaris 10, FreeBSD, AIX 5.x, HP-UX 11i, Mac OS X

Virtual Machine

  • VMWare ESXi (Windows 11 / 10)
  • VMware Fusion (Windows on macOS 14, 13, 12, 11 and 10.1x)
  • Parallels Desktop (Windows on macOS 14, 13, 12, 11 and 10.1x)

Arm®-based Platform Support

  • Windows 11
  • Linux Kernel 6.x, 5.x and 4.x
  • macOS 14, 13, 12 and 11

Android API

  • Android 3.1.x and later

Authentication

  • Local database (password only)
  • RADIUS

Encryption

  • HTTPS
  • AES-128
  • AES-256
  • HMAC
  • RSA-1024
  • SHA-1

Security Protocols

  • SNMPv3
  • SSHv2

Connector

  • CN2610/CN2650 models: 8-pin RJ45
  • CN2650I models: DB9 male

No. of Ports

  • CN2600-8 models: 8
  • CN2600-16 models: 16

Serial Standards

  • CN2610 models: RS-232
  • CN2650 models: RS-232/422/485

Operation Modes

  • Real COM mode
  • TCP Server mode
  • TCP Client mode
  • UDP mode
  • RFC2217 mode
  • Terminal mode
  • Reverse Telnet mode
  • PPP mode
  • DRDAS mode
  • Redundant COM mode
  • Disabled

Baudrate

  • 50 bps to 921.6 kbps

Data Bits

  • 5, 6, 7, 8

Stop Bits

  • 1, 1.5, 2

Parity

  • None
  • Even
  • Odd
  • Space
  • Mark

Flow Control

  • None
  • RTS/CTS
  • DTR/DSR
  • XON/XOFF

Isolation

  • CN2650I models: 2 kV
    Note:
    Each serial port has 2-kV Isolation. So, if one of them is disabled because of a surge, other ports are not affected ensuring that the device works without any drops.

RS-485 Data Direction Control

  • Automatic Data Direction Control (ADDC)

Pull High/Low Resistor for RS-485

  • 1 kilo-ohm, 150 kilo-ohms

Terminator for RS-485

  • 120 ohms

Console Port

  • RS-232 (TxD, RxD, GND), 8-pin RJ45 (19200, n, 8, 1)

RS-232

  • TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND

RS-422

  • Tx+, Tx-, Rx+, Rx-, GND

RS-485-4w

  • Tx+, Tx-, Rx+, Rx-, GND

RS-485-2w

  • Data+, Data-, GND

No. of Power Inputs

  • -2AC models: 2
  • All other models: 1

Input Current

  • -HV models: 200 mA @ 88 VDC
  • All other models: 130 mA @ 110 VAC

Input Voltage

  • -HV models: 110 VDC (88 to 300 VDC)
  • All other models: 100 to 240 VAC, 50/60 Hz

Automatic Reboot Trigger

  • Built-in WDT

Alert Tools

  • Built-in buzzer and RTC (real-time clock)

Housing

  • Metal

Installation

  • 19-inch rack mounting

Dimensions (with ears)

  • 480 x 198 x 45.5 mm (18.9 x 7.80 x 1.77 in)

Dimensions (without ears)

  • 440 x 198 x 45.5 mm (17.32 x 7.80 x 1.77 in)

Weight

  • CN2610-8/CN2650-8: 2,410 g (5.31 lb)
  • CN2610-16/CN2650-16: 2,460 g (5.42 lb)
  • CN2610-8-2AC/CN2650-8-2AC/CN2650-8-2AC-T: 2,560 g (5.64 lb)
  • CN2610-16-2AC/CN2650-16-2AC/CN2650-16-2AC-T: 2,640 g (5.82 lb)
  • CN2650I-8: 3,907 g (8.61 lb)
  • CN2650I-16: 4,046 g (8.92 lb)
  • CN2650I-8-2AC: 4,284 g (9.44 lb)
  • CN2650I-16-2AC: 4,423 g (9.75 lb)
  • CN2650I-8-HV-T: 3,848 g (8.48 lb)
  • CN2650I-16-HV-T: 3,987 g (8.79 lb)

Operating Temperature

  • Standard models:
    0 to 55°C (32 to 131°F)
  • CN2650-8-2AC-T/CN2650-16-2AC-T models:
    -40 to 75°C (-40 to 167°F)
  • CN2650I-8-HV-T/CN2650I-16-HV-T models:
    -40 to 85°C (-40 to 185°F)

Storage Temperature (package included)

  • Standard Models:
    0 to 55°C (32 to 131°F)
  • CN2650-8-2AC-T/CN2650-16-2AC-T models:
    -40 to 75°C (-40 to 167°F)
  • CN2650I-8-HV-T/CN2650I-16-HV-T models:
    -40 to 85°C (-40 to 185°F)

Ambient Relative Humidity

  • 5 to 95% (non-condensing)

EMC

  • CN2650I models: EN 55032/35
  • All other models: EN 55032/24

EMI

  • CISPR 32, FCC Part 15B Class A

EMS

  • -HV models:
    IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
    IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m
    IEC 61000-4-4 EFT: Power: 4 kV; Signal: 2 kV
    IEC 61000-4-5 Surge: Power: 2 kV; Signal: 1 kV
    IEC 61000-4-6 CS: 150 kHz to 80 MHz: 3 V/m
    IEC 61000-4-8 PFMF
  • All other models:
    IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
    IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
    IEC 61000-4-4 EFT: Power: 4 kV; Signal: 2 kV
    IEC 61000-4-5 Surge: Power: 2.5 kV; Signal: 1 kV
    IEC 61000-4-6 CS: 150 kHz to 80 MHz: 3 V/m; Signal: 3 V/m
    IEC 61000-4-8 PFMF
    IEC 61000-4-11

International Approval

  • CN2650-16-2AC models: KC

Safety

  • CN2650I models: UL 62368-1
  • All other models: UL 60950-1

Vibration

  • IEC 60068-2-6

Freefall

  • IEC 60068-2-32

Green Product

  • RoHS, CRoHS, WEEE

Time

  • CN2610-8: 831,925 hrs
  • CN2610-16: 639,332 hrs
  • CN2610-8-2AC/CN2650-8-2AC: 773,268 hrs
  • CN2610-16-2AC: 604,346 hrs
  • CN2650-8: 657,123 hrs
  • CN2650-16: 457,175 hrs
  • CN2650-16-2AC: 442,699 hrs
  • CN2650I-8: 374,652 hrs
  • CN2650I-8-2AC: 370,752 hrs
  • CN2650-8-2AC-T: 190,562 hrs
  • CN2650I-16: 248,847 hrs
  • CN2650I-16-2AC: 247,119 hrs
  • CN2650-16-2AC-T: 115,887 hrs
  • CN2650I-8-HV-T: 357,995 hrs
  • CN2650I-16-HV-T: 241,404 hrs

Standards

  • Telcordia (Bellcore) Standard TR/SR

Warranty Period

  • 5 years