Features and Benefits

  •  30 seconds to complete classic Real COM mode settings with DSU-G2
  •  2 Ethernet ports with the same IP or dual IP addresses for network redundancy
  •  Cascading Ethernet ports for easy wiring
  •  Supports nonstandard baudrates with high precision
  •  Data encryption with secure operation modes for Real COM, TCP Server, TCP Client, Pair Connection, Terminal, and Reverse Terminal
  •  One-click diagnostics for easy troubleshooting
  •  Embedded traffic monitoring for advanced data analysis
  •  10/100BaseTX (RJ45) or 100BaseFX (single mode or multi-mode with SC/ST connector), and 100Base SFP
  •  DNV, CID2, ATEX Zone 2, and IECEx compliance

Models

  • NPort IA5450-G2
  • NPort IA5450-TB-G2
  • NPort IA5450I-G2
  • NPort IA5450I-TB-G2
  • NPort IA5250-G2
  • NPort IA5250-TB-G2
  • NPort IA5250I-G2
  • NPort IA5250I-TB-G2
  • NPort IA5150-G2
  • NPort IA5150I-G2
  • NPort IA5150-S-SC-G2
  • NPort IA5150-M-SC-G2
  • NPort IA5150-SFP-G2
  • NPort IA5450-G2-T
  • NPort IA5450-TB-G2-T
  • NPort IA5450I-G2-T
  • NPort IA5450I-TB-G2-T
  • NPort IA5250-G2-T
  • NPort IA5250-TB-G2-T
  • NPort IA5250I-G2-T
  • NPort IA5250I-TB-G2-T
  • NPort IA5150-G2-T
  • NPort IA5150I-G2-T
  • NPort IA5150-S-SC-G2-T
  • NPort IA5150-M-SC-G2-T
  • NPort IA5150-SFP-G2-T

Overview

How to Buy

Click “WhatsApp Us” or “Get a Quote” above to buy NPort IA5000-G2 from APulsar Technologies, MOXA official distributor.

Purchase walk-in from our office in Petaling Jaya, or order online and enjoy fast delivery across Kuala Lumpur and the entire Malaysia.

Introduction

The NPort® IA5000-G2 device servers are designed for connecting industrial automation serial devices, such as PLCs, sensors, meters, motors, drives, barcode readers, and operator displays. The device servers are solidly built, come in a metal housing and with screw connectors, and provide full surge protection. The NPort® IA5000-G2 device servers are extremely user-friendly, making simple and reliable serial-to-Ethernet solutions possible.

Cascading Ethernet Ports Make Wiring Easy

The NPort® IA5000-G2 device servers each have two Ethernet ports that can be used as Ethernet switch ports. One port connects directly to the network or server, and the other port can be connected to either another NPort IA device server or another Ethernet device. The dual Ethernet ports help reduce wiring costs by eliminating the need to connect each device to a separate Ethernet switch.

Optical Fiber for Ethernet Communication

The NPort® IA5000-G2 Series includes 100BaseFX fiber models that support transmission distances up to 4 km for multi-mode models, and up to 40 km for single-mode models. The models also come with a built-in 100BaseTX copper port that makes configuration easier than ever. One of the models in the series supports SFP modules for additional flexibility with Ethernet port options.

Optical fiber is well-suited for industrial applications because it is immune to electromagnetic noise and interference. For environments that experience high ground loop voltages, fiber provides the best isolation protection, and because there is no danger of sparking, optical fiber is safer than copper wire in hazardous environments.

Easy Troubleshooting With One-click Log Collection

At the maintenance stage, system errors may require you to call for help. Device vendors might take a long time to troubleshoot issues because they need to collect information and then hold discussions with the technical support team. The NPort® IA5000-G2 comes with a one-click log collection function to enable logging of data, which can provide all the data that a technical support team needs to quickly troubleshoot system issues.

Relay Output Warning and Email Alerts

The built-in relay output can be used to alert administrators when the network is down, when power failure occurs, or when there is a change in the DCD or DSR serial signals. An email warning can also be issued when an abnormality is detected. These functions are valuable tools that enable maintenance engineers to react promptly to emergency situations.

Surge Protection for Serial, Ethernet, and Power

Moxa’s leading-edge surge immunity solution, which is applied to the NPort® IA5000-G2’s serial, power, and Ethernet lines, is tested and proven compliant with IEC 61000-4-5. This advanced surge protection provides a robust serial-to-Ethernet solution that can protect electrical devices from voltage spikes and resist electrical interference, such as in oil, gas, and power automation applications.

Industrial-grade Certifications

To ensure safe and reliable operation in industrial environments, the NPort® IA5000-G2 device servers have obtained various industrial certifications, including an IP30 rating for mechanical protection and UL 62368-1 safety certification for industrial control equipment. In addition, approvals are pending for ATEX, Class I Division 2, and IECEx compliance for use in hazardous locations.

Specifications

Ethernet Interface

10/100BaseT(X) Ports (RJ45 connector)

  • NPort IA5150-S-SC-G2/M-SC-G2/M-ST-G2 models: 1
  • NPort IA5000-G2 models: 2
  • Auto MDI/MDI-X connection

Magnetic Isolation Protection

  • 1.5 kV (built-in)

Optical Fiber

100BaseFX
Multi-Mode Single-Mode
Fiber Cable Type OM1 50/125 µm G.652
800 MHz x km
Typical Distance 4 km 5 km 40 km
Wavelength Typical (nm) 1300 1310
TX Range (nm) 1260 to 1360 1280 to 1340
RX Range (nm) 1100 to 1600 1100 to 1600
Optical Power TX Range (dBm) -10 to -20 0 to -5
RX Range (dBm) -3 to -32 -3 to -34
Link Budget (dB) 12 29
Dispersion Penalty (dB) 3 1
Note: When connecting a single-mode fiber transceiver, we recommend using an attenuator to prevent damage caused by excessive optical power.
Note: Compute the “typical distance” of a specific fiber transceiver as follows: Link budget (dB) > dispersion penalty (dB) + total link loss (dB).

 

Configuration Options

  • Web Console (HTTP/HTTPS)
  • Device Search Utility (DSU)
  • MCC Tool
  • Serial Console

Management

  • ARP, DHCP Client, DNS, HTTPS, ICMP, IPv4, MDNS, LLDP, SMTP, SMTPS, SNMPv1/v2c/v3, TCP/IP, UDP, SNTP, WINS

Windows Real COM Drivers

  • Windows 11, 10, 8.1, 8, 7, Vista, XP, ME, 98, and 95
  • Windows Server 2022, 2019, 2016, 2012 R2, 2012, 2008 R2, 2008, 2003, 2000, and NT

Linux Real TTY Drivers

  • Kernel versions: 6.x, 5.x, and 4.x

Fixed TTY Drivers

  • macOS versions: 14, 13, 12, and 11

Arm®-based Platform Support

  • Windows 11
  • Linux kernels 6.x, 5.x, and 4.x
  • macOS 14, 13, 12, and 11

Virtual Machine

  • VMWare ESXi (Windows 11/10/8.1/8/7 & Linux 6.x, 5.x, and 4.x)
  • VMware Fusion (Windows on macOS 14, 13, 12, and 11)
  • Parallels Desktop (Windows on macOS 14, 13, 12, and 11)

Android API

  • Android 3.1.x and later

Time Management

  • SNTP Client

Filter

  • IGMP v1/v2

MIB

  • RFC1213, RFC1317
  • Private MIB

Root of Trust

  • Secure Boot
  • True Random Number Generator (TRNG)

Authentication

  • Local database

Encryption

  • HTTPS: ECC-256, ECC-384, ECC-521, RSA-1024, RSA-2048, RSA-3072, RSA-4096, AES-128, AES-256, SHA-256, SHA-384, HMAC
  • SSH: ECC-256, ECC-384, ECC-521, RSA-2048, AES-128, AES-256, SHA-256, SHA-384, HMAC
  • SNMPv3: AES-128, SHA-256, SHA-384
  • Secure OP mode: HTTPS: ECC-256, ECC-384, ECC-521, RSA-1024, RSA-2048, RSA-3072, RSA-4096, AES-128, AES-256, SHA-256, SHA-384, HMAC
  • Config file import/export: AES-256, SHA-256, HMAC

Security Protocols

  • HTTPS (TLS 1.2)
  • SNMPv3
  • SSHv2

No. of Ports

  • NPort IA5150-G2 models: 1
  • NPort IA5250-G2 models: 2
  • NPort IA5450-G2 models: 4

Connector

  • NPort IA5150-G2 models: 1 x DB9 male
  • NPort IA5250-G2 models: 2 x DB9 male
  • NPort IA5250-TB-G2 models: 2 x 5-pin terminal block
  • NPort IA5450-G2 models: 4 x DB9 male
  • NPort IA5450-TB-G2 models: 4 x 5-pin terminal block

Serial Standards

  • RS-232/422/485 (software-selectable)

Standard Operation Modes

  • Real COM, TCP Server, TCP Client, UDP, Reverse Terminal, RFC2217, Pair Connection, Disabled

Secure Operation Modes

  • Secure Real COM, Secure TCP Server, Secure TCP Client, Reverse SSH, Secure Pair Connection

Baudrate

  • 50 bps to 921.6 kbps (supports non-standard baudrates)

Data Bits

  • 5, 6, 7, 8

Stop Bits

  • 1, 1.5, 2

Parity

  • None, Even, Odd, Space, Mark

Flow Control

  • None, RTS/CTS, DTR/DSR, RTS Toggle, XON/XOFF

RS-485 Data Direction Control

  • ADDC (automatic data direction control)

Pull High/Low Resistor for RS-485

  • 1 kilo-ohm, 150 kilo-ohms (software–configurable)

Terminator for RS-485

  • 120 ohms (software–configurable)

Isolation

  • I models: 2 kV

RS-232

  • TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND

RS-422

  • Tx+, Tx-, Rx+, Rx-, GND

RS-485-4w

  • Tx+, Tx-, Rx+, Rx-, GND

RS-485-2w

  • Data+, Data-, GND

Input Voltage

  • 12 to 48 VDC

Input Current

  • NPort IA5150-G2/IA5250-G2 models: 270 mA (max.)
  • NPort IA5250I-G2 models: 330 mA (max.)
  • NPort IA5450-G2/IA5150-SFP-G2/IA5150I-SFP-G2 models: 377 mA (max.)

Power Connector

  • 8-pin terminal block (V1+, V1-, NO, NC, GND, V2+, V2-, SG)

Contact Current Rating

  • Resistive load: 1 A @ 30 VAC

Housing

  • Metal

IP Rating

  • IP30

Dimensions

  • NPort IA5150-G2/IA5250-G2 models: 25 x 89 x 129 mm (0.98 x 3.5 x 5.07 in)
  • NPort IA5450-G2 models: 42 x 89 x 129 mm (1.65 x 3.5 x 5.07 in)

Weight

  • NPort IA5150-G2 models: 384 g (0.85 lb)
  • NPort IA5250-G2 models: 394 g (0.87 lb)
  • NPort IA5450-G2 models: 512 g (1.13 lb)

Operating Temperature

  • Standard models: -10 to 60°C (14 to 140°F)
  • Wide temp. models: -40 to 75°C (-40 to 167°F)

Storage Temperature

  • -40 to 85°C (-40 to 185°F)

Ambient Relative Humidity

  • 5 to 95% (non-condensing)

EMC

  • EN 55032/35

EMI

  • CISPR 32, FCC Part 15B Class A

EMS

  • IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV
  • IEC 61000-4-3 RS: 80 MHz to 2 GHz: 10 V/m
  • IEC 61000-4-4 EFT: Power: 4 kV; Signal: 2 kV
  • IEC 61000-4-5 Surge: Power: 2 kV
  • IEC 61000-4-6 CS: 150 kHz to 80 MHz: 10 V/m; Signal: 10 V/m
  • IEC 61000-4-8 PFMF
  • IEC 61000-4-11

Hazardous Locations

  • ATEX*, Class I Division 2*, IECEx*
    *Approval pending

Maritime

  • DNV*
    *Approval pending

Safety

  • IEC 62368-1
  • UL 62368-1
  • EN 62368-1

Vibration

  • IEC 60068-2-6
  • IEC 60068-2-64

Freefall

  • IEC 60068-2-6
  • IEC 60068-2-32
  • IEC 60068-2-34

Green Product

  • RoHS, CRoHS, WEEE

Time

  • NPort IA5150-G2(-T): 3,238,923 hrs
  • NPort IA5150I-G2(-T): 3,156,944 hrs
  • NPort IA5150-SFP-G2(-T): 3,109,327 hrs
  • NPort IA5250-TB-G2(-T): 2,943,248 hrs
  • NPort IA5250-G2(-T): 2,931,934 hrs
  • NPort IA5150-S/M-SC-G2(-T): 2,889,487 hrs
  • NPort IA5250I-TB-G2(-T): 2,809,979 hrs
  • NPort IA5250I-G2(-T): 2,799,662 hrs
  • NPort IA5450-TB-G2(-T): 2,377,791 hrs
  • NPort IA5450-G2(-T): 2,363,042 hrs
  • NPort IA5450I-TB-G2(-T): 2,208,607 hrs
  • NPort IA5450I-G2(-T): 2,195,874 hrs

Standards

  • Telcordia Standard SR-332

Warranty Period