PT-G510 Series

Features and Benefits

  • IEC 61850-3 Edition 2 Class 2 compliant
  • IEC 62439-3 Clause 4 (PRP) and Clause 5 (HSR) compliant
  • IEEE 1588 hardware time stamp supported
  • Supports IEEE C37.238 and IEC 61850-9-3 power profiles
  • GOOSE Check for easy troubleshooting
  • Built-in MMS server based on IEC 61850-90-4 switch data modeling for power SCADA
  • -40 to 75°C operating temperature range

Models

  • PT-G510-8GTX-PHR-WV
  • PT-G510-4GTX4GSFP-PHR-HV-CT
  • PT-G510-8GTX-PHR-WV-CT
  • PT-G510-8GSFP-PHR-WV-CT
  • PT-G510-8GTX-PHR-HV
  • PT-G510-4GTX4GSFP-PHR-HV
  • PT-G510-4GTX4GSFP-PHR-WV
  • PT-G510-8GSFP-PHR-WV
  • PT-G510-4GTX4GSFP-PHR-WV-CT
  • PT-G510-8GTX-PHR-HV-CT
  • PT-G510-8GSFP-PHR-HV-CT
  • PT-G510-8GSFP-PHR-HV

Overview

How to Buy

Click “WhatsApp Us” or “Get a Quote” above to buy PT-G510 from APulsar Technologies, MOXA official distributor.

In stock. Purchase walk-in from our office in Petaling Jaya, or order online and enjoy fast delivery across Kuala Lumpur and the entire Malaysia.

Introduction

The PT-G510 Series is designed to deliver the highest level of system availability and data integrity for mission-critical applications in digital substations that demand zero-recovery-time redundancy. The PT-G510 Series supports PRP/HSR to achieve seamless redundancy for substations and process automation systems. Hardware-based IEEE 1588v2 PTP is also supported for time-critical applications. Featuring a highly durable design, the PT-G510 Series is certified for IEC 61850-3 Edition 2 Class 2 to fulfill demanding requirements in substation applications.

The PT-G510 Series comes with eight 100/1000BaseT(X) Ethernet ports or 100/1000BaseSFP slots with two dedicated 100/1000BaseSFP PRP/HSR ports combined with support for a complete redundancy protocol suite including PRP, HSR, MRP, STP, MSTP, and RSTP for maximum network reliability. The PT-G510 Series further supports GOOSE Check to efficiently monitor GOOSE packets and features a built-in MMS server based on IEC 61850-90-4 switch data modeling for power SCADA systems.

Specifications

Ethernet Interface

100/1000BaseT(X) Ports (RJ45 connector)

  • PT-G510-8GTX-PHR models: 8
  • PT-G510-4GTX4GSFP-PHR models: 4

100/1000BaseSFP Ports

  • PT-G510-8GSFP-PHR models: 10
  • PT-G510-4GTX4GSFP-PHR models: 6

Standards

  • IEEE 802.3u for 100BaseT(X) and 100BaseFX
  • IEEE 802.3ab for 1000BaseT(X)
  • IEEE 802.3z for 1000BaseX
  • IEEE 802.1D-2004 for Spanning Tree Protocol
  • IEEE 802.1w for Rapid Spanning Tree Protocol
  • IEEE 802.1p for Class of Service
  • IEEE 802.1Q for VLAN Tagging
  • IEEE 802.1X for authentication
  • IEEE 802.3ad for Port Trunk with LACP
  • IEEE 802.3x for flow control

Management

  • HTTPS
  • Back Pressure Flow Control
  • DHCP Option 66/67/82
  • Fiber check
  • Flow control
  • LLDP
  • Port Mirror
  • SNMP Inform
  • BOOTP
  • DHCP Server/Client
  • HTTP
  • IPv4/IPv6
  • RARP
  • SMTP
  • SNMPv1/v2c/v3
  • Syslog
  • Telnet
  • TFTP

MIB

  • MIB-II
  • Ethernet-like MIB
  • Bridge MIB
  • P-BRIDGE MIB
  • Q-BRIDGE MIB
  • RSTP MIB
  • RMON MIB Groups 1, 2, 3, 9

Filter

  • IGMP v1/v2/v3
  • GMRP
  • GVRP
  • 802.1Q
  • QinQ VLAN

Redundancy Protocols

  • Link Aggregation
  • MSTP
  • RSTP
  • STP
  • Turbo Chain
  • Turbo Ring
  • MRP
  • HSR
  • PRP
  • Coupling
  • RSTP grouping

Security

  • RADIUS
  • TACACS+
  • SSH
  • Port Lock
  • Broadcast storm protection
  • MAB authentication
  • Sticky MAC
  • Access control list

Time Management

  • NTP Server/Client
  • SNTP
  • IEEE 1588v2 PTP (hardware-based)

Power Substation

  • GOOSE Check
  • IEC 61850 QoS
  • MMS

Priority Queues

  • 8

Max. No. of VLANs

  • 256

VLAN ID Range

  • 1 to 4094

RSTP Grouping ID Range

  • 1 to 4094

IGMP Groups

  • 4096

MAC Table Size

  • 16 K

Packet Buffer Size

  • 12 Mbits

Console Port

  • RS-232 (RJ45)

Storage Port

  • USB Type A

Input Voltage

-HV models:

  • 110-220 VAC, 110-220 VDC (88 to 300 VDC, 85 to 264 VAC)

-WV models:

  • 24-48 VDC (18 to 72 VDC)

Note: Both -HV and -WV models support dual power inputs with a single power module.

Input Current

-HV models:

  • 0.5 A @ 110-220 VAC
  • 0.3 A @ 110-220 VDC

-WV models:

  • 1.1 A @ 24-48 VDC

Alarm Contact Channels

  • Resistive load: 1 A @ 24 VDC

Overload Current Protection

  • Supported

Reverse Polarity Protection

  • Supported

IP Rating

  • IP30

Dimensions (without ears)

  • 74 x 148 x 120 mm (2.91 x 5.83 x 4.72 in)

Weight

  • 1476 g (3.25 lb)

Installation

  • DIN-rail mounting

Operating Temperature

  • -40 to 75°C (-40 to 167°F)
  • -40 to 85°C (-40 to 185°F) for 16 hrs (tested in accordance with IEC 60068-2-2)

Storage Temperature (package included)

  • -40 to 85°C (-40 to 185°F)

Ambient Relative Humidity

  • 5 to 95% (non-condensing)

EMC

  • EN 55032/35

EMI

  • CISPR 32, FCC Part 15B Class A

EMS

  • IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
  • IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
  • IEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kV
  • IEC 61000-4-5 Surge: Power: 4 kV; Signal: 4 kV
  • IEC 61000-4-6 CS: 10 V
  • IEC 61000-4-8 PFMF
  • EN 61000-4-11

Power Substation

  • IEC 61850-3 Edition 2.0 Class 2
  • IEEE 1613

Railway

  • EN 50121-4

Maritime

-WV models:

  • DNV
  • IEC 60945

Safety

  • IEC 62368-1
  • UL 62368-1

Time

  • 688,584 hrs

Standards

  • Telcordia (Bellcore) Standard TR/SR

Warranty Period

  • 5 years
Open chat
Hello 👋
Can we help you?