Features and Benefits

  • User-definable Modbus TCP Slave addressing
  • Supports RESTful API for IIoT applications
  • Supports EtherNet/IP Adapter
  • 2-port Ethernet switch for daisy-chain topologies
  • Saves time and wiring costs with peer-to-peer communications
  • Active communication with MX-AOPC UA Server
  • Supports SNMP v1/v2c
  • Easy mass deployment and configuration with ioSearch utility
  • Friendly configuration via web browser
  • Simplifies I/O management with MXIO library for Windows or Linux
  • Class I Division 2, ATEX Zone 2 certification
  • Wide operating temperature models available for -40 to 75°C (-40 to 167°F) environments

Models

  • ioLogik E1210 (In Stock) / ioLogik E1210-T
  • ioLogik E1211 (In Stock) / ioLogik E1211-T
  • ioLogik E1212 (In Stock) / ioLogik E1212-T
  • ioLogik E1213 / ioLogik E1213-T
  • ioLogik E1214 (In Stock) / ioLogik E1214-T
  • ioLogik E1240 (In Stock) / ioLogik E1240-T
  • ioLogik E1241 / ioLogik E1241-T
  • ioLogik E1242 (In Stock) / ioLogik E1242-T
  • ioLogik E1260 / ioLogik E1260-T
  • ioLogik E1262 / ioLogik E1262-T

Overview

How to Buy

Click “WhatsApp Us” or “Get a Quote” above to buy ioLogik E1200 Series from APulsar Technologies, MOXA official distributor.

In Stock. Purchase walk-in from our office in Petaling Jaya. Or order online and enjoy fast delivery across Kuala Lumpur and the entire Malaysia.

Introduction

The ioLogik E1200 Series supports the most widely used protocols for retrieving I/O data, making it suitable for diverse applications. IT engineers often use SNMP or RESTful API, while OT engineers prefer Modbus and EtherNet/IP.

With Moxa’s Smart I/O, both IT and OT teams can retrieve data from the same device. The E1200 speaks six protocols: Modbus TCP, EtherNet/IP, and Moxa AOPC for OT; SNMP, RESTful API, and Moxa MXIO library for IT. It can retrieve data and convert it into any of these protocols simultaneously, ensuring quick and flexible integration.

Daisy-Chained Ethernet I/O Connection

The E1200 features two switched Ethernet ports for downstream and upstream connections. This enables expandable daisy-chained Ethernet I/O arrays without extra switches.

You can connect devices downstream to local equipment or upstream to a control server. This setup works well in factory automation, security and surveillance, or tunnel systems. Daisy-chaining increases expandability and lowers costs by reducing switches, cabling, and labor.

Save Time and Wiring Costs with Peer-to-Peer Communications

In remote automation, the control room and sensors are often far apart. Long-distance wiring is expensive and complex.

Peer-to-peer networking maps a pair of ioLogik modules so that input values are sent directly to output channels. This eliminates extra wiring and simplifies installation.

User-Definable Modbus TCP Addressing for Painless Upgrading of Existing Systems

Many Modbus devices use fixed addresses, which can slow setup. You must locate each device’s networking details, such as I/O channels or vendor-specific addresses, before configuring a SCADA or PLC.

The E1200 supports user-definable Modbus TCP addressing, so you simply set the function and address map to match your system, reducing setup time.

Push Technology for Events

When paired with MX-AOPC UA Server, the E1200 can push event data directly to a SCADA system. Unlike polling, push technology sends updates only when changes or configured events occur. This reduces data traffic while increasing accuracy.

Specifications

Input/Output Interface

Digital Input Channels

  • 16

Isolation

  • 3k VDC or 2k Vrms

Buttons

  • Reset button

Connector

  • Screw-fastened Euroblock terminal

Sensor Type

  • Dry contact
    Wet contact (NPN or PNP)

I/O Mode

  • DI or event counter

Dry Contact

  • On: short to GND
    Off: open

Wet Contact (DI to COM)

On: 10 to 30 VDC
Off: 0 to 3 VDC

Counter Frequency

  • 250 Hz

Digital Filtering Time Interval

  • Software configurable

Points per COM

  • 8 channels

10/100BaseT(X) Ports (RJ45 connector)

  • 2, 1 MAC address (Ethernet bypass)

Magnetic Isolation Protection

  • 1.5 kV (built-in)

Configuration Options

  • Web Console (HTTP)
  • Windows Utility (ioSearch)
  • MCC Tool

Industrial Protocols

  • Modbus TCP Server (Slave)
  • Moxa AOPC (Active Tag)
  • MXIO Library
  • EtherNet/IP Adapter

Management

  • RESTful API
  • SNMPv1/v2c
  • SNMPv1 Trap
  • HTTP
  • DHCP Client
  • BOOTP
  • IPv4
  • TCP/IP
  • UDP

MIB

  • Device Settings MIB

Security

  • Access control list

Authentication

  • Local database

LED Indicators

  • Power, Ready, Port 1, Port 2

Functions Supported

  • 1, 2, 3, 4, 5, 6, 15, 16, 23

Mode

  • Server (Slave)

Max. No. of Client Connections

  • 10

Mode

  • Adapter

Max. No. of Scanner Connections

  • 9 (for read-only), 1 (for read/write)

Power Connector

  • Screw-fastened Euroblock terminal

No. of Power Inputs

  • 1

Input Voltage

  • 12 to 36 VDC

Power Consumption

  • 110 mA @ 24 VDC

Housing

  • Plastic

Dimensions

  • 27.8 x 124 x 84 mm (1.09 x 4.88 x 3.31 in)

Weight

  • 200 g (0.44 lb)

Installation

  • DIN-rail mounting
  • Wall mounting

Wiring

  • I/O cable, 16 to 26 AWG
  • Power cable, 12 to 24 AWG

Operating Temperature

  • -10 to 60°C (14 to 140°F)

Storage Temperature (package included)

  • -40 to 85°C (-40 to 185°F)
  • Ambient Relative Humidity

    • 5 to 95% (non-condensing)
  • Altitude

    • 4000 m 

EMC

  • EN 55032/24
  • EN 61000-6-2/-6-4

EMI

  • CISPR 32, FCC Part 15B Class A

EMS

  • IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
  • IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
  • IEC 61000-4-4 EFT: Power: 2 kV; Signal: 1 kV
  • IEC 61000-4-5 Surge: Power: 2 kV; Signal: 1 kV
  • IEC 61000-4-6 CS: 10 V
  • IEC 61000-4-8 PFMF

Hazardous Locations

  • ATEX
    Class I Division 2

Safety

  • UL 508

Shock

  • IEC 60068-2-27

Freefall

  • IEC 60068-2-32

Vibration

  • IEC 60068-2-6

Green Product

  • RoHS, CRoHS, WEEE

Time

  • 671,345 hrs

Standards

  • Telcordia Standard SR-332

Warranty Period

  • 5 years