IMC-21 Series

Features and Benefits

  • Multi-mode or single-mode, with SC or ST fiber connector
  • Link Fault Pass-Through (LFPT)
  • DIP switches to select FDX/HDX/10/100/Auto/Force

Models

  • IMC-21-M-SC (In Stock)
  • IMC-21-S-SC (In Stock)
  • IMC-21-M-ST

Overview

How to Buy

Click “WhatsApp Us” or “Get a Quote” above to buy IMC-21 Series from APulsar Technologies, MOXA official distributor.

In stock. Purchase walk-in from our office in Petaling Jaya, or order online and enjoy fast delivery across Kuala Lumpur and the entire Malaysia.

Introduction

The IMC-21 industrial media converters offer entry-level 10/100BaseT(X)-to-100BaseFX conversion. These converters provide reliable and stable operation in harsh industrial environments. They deliver a cost-effective solution for demanding applications.

The converters run on either 12 or 48 VDC power input. They operate reliably in temperatures from -10 to 60°C. The rugged hardware design protects your Ethernet equipment from demanding industrial conditions. You can easily mount the IMC-21 converters on a DIN rail or in distribution boxes.

Specifications

Ethernet Interface

10/100BaseT(X) Ports (RJ45 connector)

  • 1

100BaseFX Ports (multi-mode SC connector)

  •  IMC-21-M-SC: 1

100BaseFX Ports (multi-mode ST connector)

  • IMC-21-M-ST: 1

100BaseFX Ports (single-mode SC connector)

  • IMC-21-S-SC: 1

Magnetic Isolation Protection

  •  1.5 kV (built-in)

Optical Fiber

100BaseFX
Multi-Mode Single-Mode
Fiber Cable Type OM1 50/125 µm G.652
800 MHz x km
Typical Distance 4 km 5 km 40 km
Wavelength Typical (nm) 1300 1310
TX Range (nm) 1260 to 1360 1280 to 1340
RX Range (nm) 1100 to 1600 1100 to 1600
Optical Power TX Range (dBm) -10 to -20 0 to -5
RX Range (dBm) -3 to -32 -3 to -34
Link Budget (dB) 12 29
Dispersion Penalty (dB) 3 1
Note: When connecting a single-mode fiber transceiver, we recommend using an attenuator to prevent damage caused by excessive optical power.
Note: Compute the “typical distance” of a specific fiber transceiver as follows: Link budget (dB) > dispersion penalty (dB) + total link loss (dB).

Input Current

  • 12 to 48 VDC, 0.271A (Max.)

Input Voltage

  • 12 to 48 VDC

Overload Current Protection

  • Supported

Housing

  • Plastic

IP Rating

  • IP30

Dimensions

  • 25 x 109 x 97 mm (0.98 x 4.29 x 3.82 in)

Weight

  • 125 g (0.27 lb)

Installation

  • DIN-rail mounting

Operating Temperature

  • -10 to 60°C (14 to 140°F)

Storage Temperature (package included)

  • -40 to 70°C (-40 to 158°F)

Ambient Relative Humidity

  • 5 to 95% (non-condensing)

EMC

  • EN 55032/24

EMI

  • CISPR 32, FCC Part 15B Class A

EMS

  • IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV
  • IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m
  • IEC 61000-4-4 EFT: Power: 1 kV; Signal: 0.5 kV
  • IEC 61000-4-5 Surge: Power: 1 kV; Signal: 1 kV
  • IEC 61000-4-6 CS: 150 kHz to 80 MHz: 3 V/m; Signal: 3 V/m
  • IEC 61000-4-8 PFMF
  • IEC 61000-4-11

Environmental Testing

  • IEC 60068-2-1
  • IEC 60068-2-2
  • IEC 60068-2-3

Safety

  • EN 60950-1, UL 60950-1

Vibration

  • IEC 60068-2-6

Time

  • 353,000 hrs

Standards

  •  MIL-HDBK-217F

Warranty Period

  • 5 years