PTC-101 Series

Features and Benefits

Overview

The PTC-101 Ethernet-to-fiber media converters convert from 10/100BaseT(X) to 100BaseFX. Models are available with either SC, ST, or LC connectors. The PTC-101 converters eliminate the need for additional wiring, and support IEEE 802.3 and IEEE 802.3u/x protocols with 10/100M, full/half-duplex, and MDI/MDI-X auto-sensing to provide a total solution for your industrial Ethernet networks. The PTC-101 is compliant with mandatory sections of IEC 61850-3, covering operating temperature, power input voltage, surge, ESD, and vibration, as well as conformal coating and power insulation, making the media converters suitable for a variety of industrial applications.

Specifications

Ethernet Interface

10/100BaseT(X) Ports (RJ45 connector)

  • 1

100BaseFX Ports (multi-mode SC connector)

  • PTC-101-M-SC-HV/M-SC-LV: 1

100BaseFX Ports (multi-mode ST connector)

  • PTC-101-M-ST-HV/M-ST-LV: 1

100BaseFX Ports (multi-mode LC connector)

  • PTC-101-M-LC-HV/M-LC-LV: 1

100BaseFX Ports (single-mode SC connector)

  • PTC-101-S-SC-HV/S-SC-LV: 1

100BaseFX Ports (single-mode ST connector)

  • PTC-101-S-ST-HV/S-ST-LV: 1

100BaseFX Ports (single-mode LC connector)

  • PTC-101-S-LC-HV/S-LC-LV: 1

Magnetic Isolation Protection

  • 1.5 kV (built-in)

Input Voltage

  • LV models: 20 to 72 VDC
  • HV models: 100 to 240 VAC/VDC (85 to 264 VAC, 88 to 300 VDC)

Input Current

  • LV-DC models: 150 mA @ 20 VDC
  • HV-AC models: 350 to 200 mA @ 100 to 240 VAC
  • HV-DC models: 350 to 200 mA @ 100 to 240 VDC

Overload Current Protection

  • Supported

Power Consumption

  • LV-DC models: 150 mA @ 20 VDC
  • HV-AC models: 350 to 200 mA @ 100 to 240 VAC
  • HV-DC models: 350 to 200 mA @ 100 to 240 VAC

Housing

  • Metal

Dimensions 

  • 152.15 x 126.46 x 66.65 mm (5.99 x 4.86 x 2.62 in)

Weight

  • Product With Package: 952 g (2.09 lb)
  • Product Only: 785 g (1.73 lb)

Installation

  • DIN-rail mounting

Operating Temperature

  • -40 to 85°C (-40 to 185°F)

Storage Temperature (package included)

  • -40 to 85°C (-40 to 185°F)

Ambient Relative Humidity

  • 5 to 95% (non-condensing)

EMC

  • EN 55032/35

EMI

  • CISPR 32, FCC Part 15B Class A

EMS

  • IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
  • IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m
  • IEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kV
  • IEC 61000-4-5 Surge: Power: 4 kV; Signal: 4 kV
  • IEC 61000-4-6 CS: 150 kHz to 80 MHz: 10 V/m; Signal: 10 V/m
  • IEC 61000-4-8 PFMF
  • IEC 61000-4-11

Environmental Testing

  • IEC 60068-2-1
  • IEC 60068-2-14
  • IEC 60068-2-3

Safety

  • EN 62368-1
  • UL 62368-1
  • UL 60950-1

Vibration

  • IEC 60068-2-6

Power Substation

  • IEC 61850-3

Time

  • 4,660,534 hrs

Standards

  • Telcordia SR332

Warranty Period

  • 5 years