Delta RT Series 5/6/8/10 kVA

Features and Benefits

Overview

Introducing the Amplon RT Series 5-10 kVA UPS: Compact yet powerful, it provides a unity output power factor and top efficiency, with up to 95.5% AC-AC efficiency. It also features Li-ion battery compatibility for enhanced density and sustainability. With optional complete power solutions like the Maintenance Bypass Breaker and Rack Remote Power Panel integration, it ensures seamless operation for critical applications.

Specifications

Model

RT-5K / RT-6K / RT-8K / RT-10K

Online double-conversion

RT-5K

  • 5 kVA / 5 kW

RT-6K

  • 6 kVA / 6 kW

RT-8K

  • 8 kVA / 8 kW

RT-10K

  • 10 kVA / 10 kW

Parallel Configuration

  • Up to 4 units

Nominal Voltage

  • 200/ 208/ 220/ 230/ 240 Vac, 1P2W+PE

Voltage Range

  • 175-280 Vac (100% load)
  • 100-175 Vac (with derating to 50-100% load)

Frequency Range

  • 40~70 Hz

Total Harmonic Distortion (THDi)

  • < 3%

Power Factor

  • > 99% (100% load)

Connection

  • Input terminal

Nominal Voltage

  • 200/ 208/ 220/ 230/ 240 Vac, 1P2W+PE

Voltage Regulation

  • ±1%

Frequency

  • 50/60 ± 0.05 Hz

Total Harmonic Distortion (THDv)

  • < 2% (linear load)
  • < 4% (non-linear load)

Power Factor

  • 1

Connection

Standard Runtime Model

  • RT-5K/6K: C13 x6, C19 x2, Terminal x1, Programmable C19 outlet x1
  • RT-8K/10K: C13 x6, C19 x4, Terminal x1, Programmable C19 outlet x1

Extended Runtime Model:

  • Terminal x1, Programmable terminal x1

Overload Capability

  • 106-125%: 5 mins
  • 126-150%: 1 min
  • > 150%: 500 ms

Current Crest Ratio

  • 3:1

Online Mode

  • Up to 95.5%

ECO Mode

  • Up to 99%

Battery Type

  • VRLA/ Lithium-ion

Nominal Voltage

Standard Runtime Model:

  • RT-5K/6K: 192 Vdc
  • RT-8K/10K: 240 Vdc

 

Extended Runtime Model:

  • 144 Vdc, 192-264 Vdc

Charge Current

Standard Runtime Model:

  • RT-5K/6K: 1 A (default), up to 8 A
  • RT-8K/10K: 1.5 A (default), up to 8 A

Extended Runtime Model:

  • Up to 8 A

 

Display

  • Graphical LCD display with LED indicators

Port

  • USB
  • RS-232
  • RS-485
  • Mini Slot
  • REPO
  • Input dry contact x1
  • Output dry contact x3

Dimensions (W x D x H)
Standard Runtime Model:

  • RT-5K/6K: 440 x 665 x 176 mm
  • RT-8K/10K: 440 x 750 x 218 mm

Extended Runtime Model:

  • RT-5K/6K: 440 x 430 x 88.2 mm
  • RT-8K/10K: 440 x 565 x 88.2 mm

Weight

Standard Runtime Model:

  • RT-5K/6K: 54 kg
  • RT-8K/10K: 85.5 kg

Extended Runtime Model:

  • RT-5K/6K: 10.9 kg
  • RT-8K/10K: 15.2 kg

Operating Temperature

  • 0 to 55°C (45 to 55°C de-rating to 75% load)
  • Operating temperature < 32°C (Derating to 70% load)

Humidity

  • 5-95% (non-condensing)

Audible Noise

  • RT-5K/6K: < 48 dBA
  • RT-8K/10K: < 50 dBA

Altitude 

  • 0-3000 m (derating 1%/100 m from 1000-3000 m)

Ingress Protection

  • IP20

Safety:

  • CE, UKCA, TISI, RCM

EMC:

  • IEC 62040-2

Performance:

  • IEC 62040-3

Sustainability:

  • RoHS, REACH