HARDWARE FAQ “MOXA INDUSTRIAL SWITCHES”

Unmanaged – A switch without management features. It is used when it is necessary to combine several Ethernet devices into a single system. Moxa unmanaged switches are presented in seriesEDS-200, EDS-300 andEDS-2000.

How to connect a Modbus RTU device to an Ethernet network?

This option requires an MGate protocol converter. You can use the Modbus TCP protocol to communicate with Modbus RTU devices through the gateway. There are many ” Modbus gateways ” available in the automation market that provide Modbus TCP connectivity for Modbus TCP slaves. When the gateway receives a Modbus TCP request, it converts the packet to Modbus RTU and immediately sends it to the Modbus RTU devices.

How to convert Modbus RTU to Modbus ASCII using MGate?

Moxa’s MGate MB3270 and MB3660 Modbus gateways can be used to convert Modbus RTU to Modbus ASCII (serial redirection). If two devices are separated by a long distance, protocol conversion can be achieved by coupling two MGates using an Ethernet connection.

How to update firmware on NPort devices?

Step 1: To update the NPort firmware, run the NPort Administrator utility. Right-click on the NPort and select the Upgrade Firmware option to start the firmware upgrade.

What is the maximum cable length for RS-232 powered devices?

Devices powered by the computer’s RS-232 port are powered by the Tx, RTS, and DTR lines. In general, the cable length should not exceed 15 meters at a speed of 9600bps. If you use a longer cable length, the transmitted power may not be enough to power the device.